Two way Inlet Breeching
Two way Inlet Breeching

Two way Inlet Breeching

Two way Inlet Breeching Specification

  • Installation Type
  • Wall mounted
  • Voltage
  • Not required (mechanical device)
  • Coverage Area
  • Varies depending on hydrant network design
  • Fire Class
  • Suitable for Class A and Class B fires
  • Control Type
  • Manual operation via coupling and valves
  • Shape
  • Rectangular body with dual inlet stubs
  • Coating Type
  • Red epoxy/polyurethane painted for corrosion resistance
  • Operating Pressure
  • Up to 20 bar
  • Application
  • Used for firefighting systems, specifically to act as an inlet for fire brigade hoses to supply water into the buildings fire hydrant system.
  • Max Flow Rate
  • Up to 900 LPM (Liters Per Minute)
  • Diameter
  • 2.5 inches (BS inlet connection)
  • Capacity
  • Not rated by volume; determined by connected system
  • Pressure
  • Standard working pressure: 10 bar; Test pressure: up to 20 bar
 
 

About Two way Inlet Breeching

Being a client-centric organization, we are engaged in manufacturing, exporting and supplying the best quality Two way Inlet Breeching. Our offered inlet breaching valve is manufactured in accordance with the set norms and regulations. The breeching inlet manufactured by us is highly appreciated in various fire fighting applications. Our offered product range is made available to the patrons as per the set time frame. Quality checked at various levels of manufacturing, our offered Two way Inlet Breeching is developed as per the definite demands of our customers.

Features:

  • Rust resistance

  • Seamless finish

  • Longer service life

  • High performance under extreme conditions


 The specifications of our two way inlet breaching is tabulated below:

Technical Specifications


WVPL - 503

Size

63mm

Reference Standard

IS : 904

M.O.C

Cast Iron / Gun Metal

Inlet

Two Male Instantaneous Inlet of 63 mm With Built in N.R.V

Outlet

Flanged 100mm

M.O.C For NRV

GM TO IS 318 LTB-II

Approval



2-way valve "A"

Flanged 100mm BS4504 PN16

2-way valve "B"

Flanged 4" BS Table D

2-way valve "C"

Screwed 4" BSPT



Efficient Fire Response Solution

Engineered for swift water delivery, the Two Way Inlet Breeching ensures that firefighters can quickly augment a buildings hydrant system during fires. Its dual inlets allow connection of fire brigade hoses, facilitating high-volume water flow for effective emergency response.


Robust Construction and Reliable Performance

Manufactured from high-grade materials with a protective red epoxy/polyurethane finish, this inlet breeching withstands challenging environments. Its 2.5-inch inlet and capacity for up to 900 LPM make it suitable for high-pressure operations and consistent fire safety performance.


Ideal for Diverse Building Types

With a wall-mounted, rectangular design, the Two Way Inlet Breeching is adaptable for residential, commercial, and industrial structures. Its simple manual operation and durable construction help ensure reliable integration into various fire hydrant system networks across India.

FAQs of Two way Inlet Breeching:


Q: How does the Two Way Inlet Breeching function during a fire emergency?

A: When a fire occurs, firefighters connect their hoses to the two inlets of the breeching. This allows them to manually supply water from fire engines directly into the buildings hydrant system, significantly bolstering onsite fire containment efforts.

Q: What types of fires can this breeching be used for?

A: The Two Way Inlet Breeching is designed for use in systems combating both Class A (ordinary combustibles) and Class B (flammable liquids) fires, providing flexibility for various commercial and industrial applications.

Q: When should the Two Way Inlet Breeching be installed in a building?

A: Installation should be completed during the setup of the buildings fire hydrant network. It is an essential component, especially in structures where fire brigade intervention may be necessary for emergency water supply.

Q: Where is the Two Way Inlet Breeching typically mounted?

A: This device is wall mounted, usually on the exterior of buildings in accessible locations specified by fire safety codes, allowing rapid connection by firefighters upon arrival.

Q: What is the installation process for the breeching inlet?

A: The unit is secured to the wall at a designated hydrant location using appropriate mounting hardware. Connections to the internal fire hydrant system are established to ensure seamless water flow from the fire brigade inlets.

Q: How does the red epoxy/polyurethane coating benefit the device?

A: The coating protects the inlet breeching from corrosion and harsh weather conditions, extending its service life and ensuring dependable operation over time.

Q: What are the advantages of using a Two Way Inlet Breeching in firefighting systems?

A: It provides a direct, manual method for fire brigades to supplement a buildings hydrant water supply quickly, supports high flow rates (up to 900 LPM), and maintains safety performance even under high-pressure scenarios.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in BREECHING INLETS Category

Fire Brigade Inlet One Way Inlet Breaching

Fire Brigade Inlet One Way Inlet Breaching

Pressure : Up to 12 Bar

Technology : Mechanical valve interface, Standardised hose connection

Installation Type : Wall Mounted/Surface Mounted

Mounting Type : Wall Mounted

Max Flow Rate : Up to 900 LPM (Litres Per Minute)

Diameter : 63 mm (2.5 inch)

Four Way Inlet Breeching

Four Way Inlet Breeching

Pressure : 14 kgf/cm test pressure

Technology : Wet riser system compatibility

Installation Type : Wall/floor mounted

Mounting Type : Surface mount

Max Flow Rate : Up to 900 LPM (Litres Per Minute)

Diameter : 100 mm (inlet female), 150 mm (main outlet male)

Fire Brigade Inlet Three Way Inlet Breaching

Fire Brigade Inlet Three Way Inlet Breaching

Pressure : Tested up to 21 kg/cm (300 psi)

Technology : Hydraulically operated with manually controlled valves

Installation Type : Surface mounted on building exterior or hydrant point

Mounting Type : Wall/Surface mountable

Max Flow Rate : Up to 900 LPM (Litres Per Minute)

Diameter : Inlet diameter 100 mm (4 inch), Outlets 63 mm (2.5 inch) male coupling