BREECHING INLETS

We are an ISO 9001:2008 certified industry, engrossed in providing high class Breeching Inlets like two way inlet breeching, four way inlet breeching etc. These inlets are manufactured using the best quality components under the proper surveillance of deft team members. These inlets provide excellent facility to route water through dry riser system installed at the exteriors of buildings. The offered Breeching Inlets can be availed from us in multitude of specifications at economical prices.


Key points:


  • Rugged design
  • Excellent finish
  • Simple installation
  • Highly durable
Product Image (22)

Fire Brigade Inlet Three Way Inlet Breaching

  • Application:Fire fighting system, used for connecting fire hoses to water supply during emergencies
  • Coating Type:Epoxy powder coated/Red paint finish
  • Control Type:Manual
  • Coverage Area:Depends on the fire hose and nozzle; typically serves large area protection
  • Installation Type:Surface mounted on building exterior or hydrant point
  • Max Flow Rate:Up to 900 LPM (Litres Per Minute)
  • Mounting Type:Wall/Surface mountable
  • Operating Pressure:~10 to 12 kg/cm (142 to 170 psi)
Product Image (23)

Fire Brigade Inlet One Way Inlet Breaching

  • Control Type:Manual Hose Coupling
  • Diameter:63 mm (2.5 inch)
  • Installation Type:Wall Mounted/Surface Mounted
  • Max Flow Rate:Up to 900 LPM (Litres Per Minute)
  • Operating Pressure:10 to 12 Bar
  • Pressure:Up to 12 Bar
  • Shape:Angular/Breeching Type
  • Technology:Mechanical valve interface, Standardised hose connection
Product Image (W-14)

Four Way Inlet Breeching

  • Control Type:Manual
  • Diameter:100 mm (inlet female), 150 mm (main outlet male)
  • Fire Class:Class A, B, C
  • Fire Extinguisher Type:Inlet breeching for wet riser hydrant
  • Installation Type:Wall/floor mounted
  • Pressure:14 kgf/cm test pressure
  • Shape:Rectangular (body), with round inlets
  • Technology:Wet riser system compatibility
Product Image (W-13)

Two way Inlet Breeching

  • Application:Used for firefighting systems, specifically to act as an inlet for fire brigade hoses to supply water into the buildings fire hydrant system.
  • Capacity:Not rated by volume; determined by connected system
  • Coating Type:Red epoxy/polyurethane painted for corrosion resistance
  • Control Type:Manual operation via coupling and valves
  • Coverage Area:Varies depending on hydrant network design
  • Installation Type:Wall mounted
  • Max Flow Rate:Up to 900 LPM (Liters Per Minute)
  • Operating Pressure:Up to 20 bar
X